Deciphering the impact of contaminating microbiota in DNA extraction reagents on metagenomic next-generation sequencing workflows

Abstract
The widespread adoption of metagenomic next-generation sequencing has revolutionized microbial detection, yet contaminating DNA in laboratory reagents poses significant challenges for result interpretation. This study investigated microbial contamination profiles across four commercial DNA extraction reagent brands (M, Q, R, and Z) and assessed batch-to-batch variability. Extraction blanks were generated using molecular-grade water or ZymoBIOMICS Spike-in Control I as input materials. Analysis revealed distinct background microbiota profiles between brands, with some containing common pathogenic species that could affect clinical interpretation. Notably, background contamination patterns varied significantly between different lots of the same brand, highlighting the need for lot-specific microbiota profiling. Site-specific environmental contaminants were identified through analysis of 30 control samples from a single study site. Additionally, comparison of blood samples from healthy individuals with control samples suggested no evidence of a consistent blood microbiome, suggesting that "extraction blanks" may serve as negative controls in clinical metagenomic testing of sterile liquid biopsy samples. These findings emphasize the importance of including negative controls in every run and underscore the need for manufacturers to provide comprehensive background microbiota data for each reagent lot to optimize clinical interpretation and minimize false-positive results.
Importance: Metagenomic next-generation sequencing (mNGS) has revolutionized pathogen detection and microbiome studies, but contamination from DNA extraction reagents remains a critical challenge. This study highlights the significant variability in background microbiota profiles across reagent brands and manufacturing lots, emphasizing the need for manufacturers to provide detailed contamination profiles. Our findings underscore the importance of implementing extraction blanks as standard controls and incorporating bioinformatics tools to account for background noise. These measures are essential to enhance the reliability of mNGS results and prevent diagnostic errors, particularly in clinical settings where contamination could mask or mimic pathogen signals. Additionally, our confirmation that healthy blood lacks a consistent microbiome helps streamline control selection in clinical testing protocols, potentially reducing costs and complexity in clinical mNGS workflows.
Keywords: DNA extraction reagents; background microbiota; bioinformatics; clinical diagnostics; contamination; lot variability; mNGS; microbiome.

mNGS 工作流程中汙染來源的動態特性。研究強調,試劑背景並非恆定不變,而是隨不同廠牌及製造批次而波動;因此,實驗室必須針對每一批次實施監控。此外,透過比較健康個體血液樣本與對照組,研究確認血液中的微生物讀數主要源自外源性汙染,而非來自人體內源性微生物。最終建議以「萃取空白」取代健康血液,作為常規檢測的標準陰性對照,以優化病原體鑑定的準確性。

相關文章

▲至頂